CDS # Definition des materiaux MATERIAU BETON B45 FCK 45 TITRE "Beton B45" PRECONTRAINT OUI FIN_MATERIAU MATERIAU ACIER acier500 Fyk 500 titre "acier 500" FIN_MATERIAU MATERIAU PRECONTRAINTE mat_prec FP01K 1560 # MPA FPK 1766 # MPA TITRE "precontainte" FIN_MATERIAU EDITER MATERIAUX TOUS # Definition des sections SECTION sec_rectangulaire TITRE "section rectangulaire" CONTOUR contour_1 TITRE "contour externe" CAISSON H_TOTALE 2.0 L_TOTALE 8.0 H_EXTREMITE_ENCORBELLEMENT 0.3 H_ORIGINE_ENCORBELLEMENT 0.4 L_ENCORBELLEMENT 1.2 E_EXTRADOS 0.4 E_INTRADOS 0.25 E_AME 0.3 L_INTRADOS 4.0 CRETE 0.2 L_GI 0.4 H_GI 0.2 L_GE 0.3 H_GE 0.25 H_JOUE 0.3 L_JOUE 0.3 FIN_CAISSON GAINES gaine1 TITRE "gaine1" DIAMETRE 120. #7C15, extérieure, non adhérente, gainée, graissé, injection au coulis POINTS NUMERO 1 Y -1.975 Z -1.675 NUMERO 2 Y -2.1 Z -1.35 NUMERO 3 Y 1.975 Z -1.675 NUMERO 4 Y 2.1 Z -1.35 NUMERO 5 Y -1.8 Z -1.85 NUMERO 6 Y -1.5 Z -1.85 NUMERO 7 Y 1.8 Z -1.85 NUMERO 8 Y 1.5 Z -1.85 NUMERO 9 Y 1.2 Z -1.85 NUMERO 10 Y -1.2 Z -1.85 FIN_POINTS PRECONTRAINTE p TITRE "cable" POINTS NUMERO 11 Y -1.975 Z -1.675 NUMERO 12 Y -2.1 Z -1.35 NUMERO 13 Y 1.975 Z -1.675 NUMERO 14 Y 2.1 Z -1.35 NUMERO 15 Y -1.8 Z -1.85 NUMERO 16 Y -1.6 Z -1.85 NUMERO 17 Y 1.8 Z -1.85 NUMERO 18 Y 1.6 Z -1.85 NUMERO 19 Y 1.2 Z -1.85 NUMERO 20 Y -1.2 Z -1.85 FIN_POINTS AIRE 2850. # mm2 MATERIAU mat_prec FIN_PRECONTRAINTE FIN_GAINES FERRAILLAGE ferext1 TITRE "FERRAILLAGE AUTOMATIQUE EXTRADOS" OPTION_FERRAILLAGE_AUTOMATIQUE DISPOSITION SUPERIEURE STRICTE ENROBAGE_MINIMAL 30 E_MAX 0.4 E_MIN 0.07 SELECTION P_25 P_32 FIN_SELECTION FIN_OPTION_FERRAILLAGE_AUTOMATIQUE MATERIAU acier500 FIN_FERRAILLAGE FERRAILLAGE ferint2 TITRE "FERRAILLAGE AUTOMATIQUE INTRADOS" OPTION_FERRAILLAGE_AUTOMATIQUE DISPOSITION INFERIEURE STRICTE ENROBAGE_MINIMAL 30 E_MAX 0.3 E_MIN 0.07 SELECTION P_25 P_32 FIN_SELECTION FIN_OPTION_FERRAILLAGE_AUTOMATIQUE MATERIAU acier500 FIN_FERRAILLAGE MATERIAU B45 FIN_CONTOUR FIN_SECTION SOLLICITATIONS sous_tension SECTION sec_rectangulaire TITRE "sous_tension" REPERE_EFFORTS BRUT PRECONTRAINTE HYPERSTATIQUE POSTENSION ETAT_LIMITE ELS QUASIPERMANENT SITUATION EXPLOITATION INFINI A_PONDERER EFFORT G TITRE "poids propre" N 0.0 My 28.0 FIN_EFFORT EFFORTS P TITRE "P" N 0 MY 0.0 TENSIONS PRECONTRAINTE p POINT 11 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 12 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 13 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 14 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 15 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 16 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 17 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 18 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 19 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 20 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, FIN_TENSIONS FIN_EFFORTS FIN_ETAT_LIMITE FIN_SOLLICITATIONS SOLLICITATIONS ventlat1 SECTION sec_rectangulaire TITRE "vent lateral 1" REPERE_EFFORTS BRUT PRECONTRAINTE HYPERSTATIQUE POSTENSION ETAT_LIMITE ELS QUASIPERMANENT SITUATION EXPLOITATION INFINI A_PONDERER EFFORT G TITRE "poids propre" N 0.0 My 28.0 FIN_EFFORT EFFORT Q TITRE "vent" N 0.0 Mz 0.755 FIN_EFFORT EFFORTS P TITRE "P" N 0 MY 0.0 TENSIONS PRECONTRAINTE p POINT 11 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 12 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 13 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 14 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 15 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 16 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 17 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 18 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 19 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 20 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, FIN_TENSIONS FIN_EFFORTS FIN_ETAT_LIMITE FIN_SOLLICITATIONS SOLLICITATIONS charge SECTION sec_rectangulaire TITRE "charge" REPERE_EFFORTS BRUT PRECONTRAINTE HYPERSTATIQUE POSTENSION ETAT_LIMITE ELU DURABLE SITUATION EXPLOITATION SERVICE A_PONDERER EFFORT G TITRE "poids propre" N 0.0 My 28.0 FIN_EFFORT EFFORT Q TITRE "charg" N 0.0 My 12.0 FIN_EFFORT EFFORT Q TITRE "vent" N 0.0 Mz 0.755 FIN_EFFORT EFFORTS P TITRE "P" N 0 MY 0.0 TENSIONS PRECONTRAINTE p POINT 11 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 12 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 13 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 14 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 15 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 16 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 19 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, PRECONTRAINTE p POINT 20 TENSION 1000 INJECTE 1.0 # Cable l, tension en MPa, FIN_TENSIONS FIN_EFFORTS FIN_ETAT_LIMITE FIN_SOLLICITATIONS # Dimensionnemnt DIMENSIONNEMENT sec_rectangulaire SOLLICITATIONS charge SOLLICITATIONS ventlat1 SOLLICITATIONS sous_tension FIN_DIMENSIONNEMENT EDITER SECTIONS TOUTES # Justifications JUSTIFICATION sec_rectangulaire INTERACTIONS FIXER Mz 0.75599 DEFORMATIONS NON_BORNEES SOLLICITATIONS charge SOLLICITATIONS ventlat1 SOLLICITATIONS sous_tension FIN_JUSTIFICATION FIN_CDS